Page banner

2-Way Power Dividers/Combiners

PWR-LINE ™ 2 Way Power Dividers and Combiners deliver high-power dividing and combining capabilities of up to 800 watts CW. Featuring internal high-power matched isolation resistors and continuous full-band operation, these PNW dividers/combiners—much like our 4 Way Power Dividers and Combiners—offer excellent performance and reliability. Moreover, their compact designs allow them to operate effectively in a variety of environments, including Medical, Industrial, Commercial Wireless, Military, and Space applications.

Standard Environmental Conditions

Operating Temperature: -55 to +85°C

Storage Temperature: -65 to +100°C

Humidity: 95% relative humidity, non-condensing

Vibration: 7 g's rms, 50-5000 CPS per MIL-STD-810B, Method 514, Procedure 5

Features

  • Easy System Integration
  • Designed To Meet MIL-E-5400,MILP-23971
  • Wide Band Operation
  • Excellent High Power Capability
P3 2-Way Power Dividers/Combiners

Series Selection Chart

Browse technical specifications and datasheets for our 2-Way Power Dividers/Combiners.

Freq.(Mhz)Part NumberPower(Watts)Amplitude Balance(±dB Max)Phase Balance(Deg. Max)Isolation(dB Min.)Insertion Loss(dB Max)VSWR(Max)Standard ConnectorsDatasheet
10-1000PNW2-10-1000-S2502500.2510-1511.3-2.0SMA/SMA
20-1000PNW2-20-1000-R4NN4000.255150.251.35N/N
30-520PNW2-30-520-2KNSC20000,305150.61.35N/SC
80-1000PNW2-80-1000-S2502500.2310-200.81.3SMA/SMA
100-160PNW2-100-160-S2502500.23200.41.25SMA/SMA
100-400PNW2-100-400-1KN10000.13190.51.35N/N
160-320PNW2-160-320-S2502500.23200.41.2SMA/SMA
150-300PNW2-150-300-S2502500.14200.41.2SMA/SMA
200-400PNW2-200-400-S2502500.24150.41.25SMA/SMA
300-600PNW2-300-600-S2502500.24180.41.25SMA/SMA
400-700PNW2-400-700-S2502000.13180.31.25SMA/SMA
400-6000PNW2-400-6000-S50500.25200.51.5SMA/SMA
500-1000PNW2-500-1000-S30300.12220.21.3SMA/SMA
500-1000PNW2-500-1000-N1KT10000.25140.251.35N/N
500-4000PNW2-500-4000-S30300.14200.21.3SMA/SMA
500-4000PNW2-500-4000-N30300.14200.21.3N/N
640-1200PNW2-640-1200-S2502000.23150.41.25SMA/SMA
800-1200PNW2-800-1200-N2502500.25150.51.4N/N
800-2000PNW2-800-2000-N5005000.255150.61.4N/N
800-2300PNW2-800-2300-S1001000.253200.41.25SMA/SMA
950-1225PNW2-950-1225-N1K10000.255150.51.4N/N
1020-1030PNW2-1020-1040-250S2500.14200.251.25SMA/SMA
1000-2000PNW2-1000-2000-S30300.13220.251.25SMA/SMAN/A
1000-2000PNW2-1000-2000-S2502500.24160.31.25SMA/SMA
1000-2000PNW2-1000-2000-N5005000.23150.351.25N/N
1000-2000PNW2-1000-2000-NSC8008000.23150.41.3N/SC
2000-4000PNW2-2000-4000-S30300.10.2200.31.3SMA/SMA
2000-4000PNW2-2000-4000-S1001000.23200.51.25SMA/SMA
2000-8000PNW2-2000-8000-S30300.14200.41.35SMA/SMA
2000-8000PNW2-2000-8000-S1001000.255120.41.3SMA/SMA
2000-8000PNW2-2K-8K-R2S2000.23180.61.3SMA/SMA
2000-8000PNW2-2K-8K-R325NS3250.23180.61.3SMA/N
2000-18000PNW2-2000-18000-S30300.1551711.5SMA/SMA
2200-2400PNW2-2200-2400-1N10.23200.31.3N/N
3000-5000PNW2-3000-5000-S30300.14200.351.3SMA/SMAN/A
4000-8000PNW2-4000-8000-S30300.14200.351.3SMA/SMAN/A
7000-12400PNW2-7000-12400-S30300.15200.41.35SMA/SMA
8000-12000PNW2-8000-12000-S1001000.14200.31.25SMA/SMA
8000-12000PNW2-8000-12000-N1001000.14200.31.25N/N
8000-18000PNW2-8000-18000-S30300.15200.61.4SMA/SMA
12000-18000PNW2-12000-18000-S30300.155200.61.4SMA/SMAN/A